Sunday, September 8, 2019

Switching point for work place - Fluid Power Lab Report

Switching point for work place - Fluid Power - Lab Report Example 1V2, 1V3,1V4 and 1V5 record multiple switching points when tested on mild steel, stainless steel, aluminum, brass and copper work pieces and no points are recorded on plastic, cardboard and rubber. No hysteresis is recorded on plastic, cardboard and rubber. When dealing with magnetic sensors, it is important understand that there is a possibility of several switching points being existent. This can eventually result into multiple counting when counters are used. This effect is dependent on the strength of the field of the magnet used and the distance between the magnet and the proximity of the sensor. Attaching the magnet with the correct orientation of the axis helps to prevent the ambiguity of the output signal. The selection of sensors is a major factor that must be taken into account when looking for industrial solutions. The choice of the sensor is very crucial when performing any installations in an

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.